What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND TWO SKIN DENTS, AT STATION 265 TO 277 ABOVE STRINGER 11 R AND 13 R. CUTOUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR. REPAIRED PER SRM 53-00-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND TWO SKIN DENTS, AT STATION 265 TO 277 ABOVE STRINGER 11 R AND 13 R. CUTOUT DAMAGED SKIN AND INSTALLED DOUBLER REPAIR. REPAIRED PER SRM 53-00-01. (M)