As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 40 INCH CORRODED AREA ON FLOOR BEAM AT BS 328. REMOVED CORRODED AREA, INSTALLED REPAIR PARTS COMPLETED REPAIR. REPAIRED PER SRM 53-10-51, FIG 205. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)