What was found
PIT - DURING Q-3/C-5 CHECK INSPECTION, FOUND LEVEL 1 CORROSION AT STATION 446 NEAR ALT STATIC PORT. PREVIOUSLY RE WORKED FROM LAV SPILL. CORROSION TASK NR C51-53300. SPLICED IN NEW SECTION OF LONGERON PER SRM 53-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-3/C-5 CHECK INSPECTION, FOUND LEVEL 1 CORROSION AT STATION 446 NEAR ALT STATIC PORT. PREVIOUSLY RE WORKED FROM LAV SPILL. CORROSION TASK NR C51-53300. SPLICED IN NEW SECTION OF LONGERON PER SRM 53-10-2. (M)