What was found
INT - DURING Q-5 CHECK VISUAL AND EDDY CURRENT INSPECTION, FOUND .25 INCH LONG SKIN CRACK ON VISUAL INSPECTION AND .625 INCH LONG GUSSET CRACK LEFT C-D WINDOW POST SKIN AND GUSSET BS APPROX 219.8 BY EDDY CURRENT. REMOVED DAMAGED AREA AND INSTALLED FILLERS AND DOUBLERS. REPAIRED PER EEA 40239. (M)