INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND DENT 3.5 INCHES BY 4.75 INCHES, STATION 344 AT STRINGER 19R. INSTALLED DOUBLER. REPAIRED PER SRM 53-00-01. (M)