What was found
PIT - DURING Q1/C6 INSPECTION, FOUND 4.75 INCH CRACK JUST OUTBOARD OF NR 7 SLAT TRACK CUT-OUT LEADING EDGE SKIN. INSTALLED INTERNAL AND EXTERNAL DOUBLERS PER SRM 57-06A, FIGURE 1, AND USAIR EA NR 31672. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q1/C6 INSPECTION, FOUND 4.75 INCH CRACK JUST OUTBOARD OF NR 7 SLAT TRACK CUT-OUT LEADING EDGE SKIN. INSTALLED INTERNAL AND EXTERNAL DOUBLERS PER SRM 57-06A, FIGURE 1, AND USAIR EA NR 31672. (X)