What was found
PIT - DURING APU MODIFICATION TRACK, FOUND CORROSION ON FLOOR BEAM, BETWEEN STATION 4850 AND 5305 AND BL 0. CUT OUT CORRODED SECTION OF BEAM AND SPLICED IN NEW 'T' EXTENSION PER SRM 51-70-06. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING APU MODIFICATION TRACK, FOUND CORROSION ON FLOOR BEAM, BETWEEN STATION 4850 AND 5305 AND BL 0. CUT OUT CORRODED SECTION OF BEAM AND SPLICED IN NEW 'T' EXTENSION PER SRM 51-70-06. (M)