INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 74 INCHES BY .5 INCHES CORRODED AREA BS 344 LBL 55 - RBL 21, ON FLOOR BEAM. FABRICATED T-CAP AND REPAIR ANGLE AND INSTALLED. REPAIRED PER TR 53-10-3, CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)