What was found
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND 3 INCH BY .25 INCH HOLE GOUGED IN OUTBOARD J-SECTION OF STRINGER, STA 1050, STR 27L. FORMED AND INSTALLED DOUBLER FOR J-LEG OF STRINGER, REPAIRED PER SRM 53-10-3, FIGURE 1. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND 3 INCH BY .25 INCH HOLE GOUGED IN OUTBOARD J-SECTION OF STRINGER, STA 1050, STR 27L. FORMED AND INSTALLED DOUBLER FOR J-LEG OF STRINGER, REPAIRED PER SRM 53-10-3, FIGURE 1. (X)