What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 24 INCH FORWARD ENTRY DOOR TRANSITION ANGLE. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-40-3. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 24 INCH FORWARD ENTRY DOOR TRANSITION ANGLE. INSTALLED FILLER AND DOUBLER, REPAIRED PER SRM 51-40-3. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)