What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORRODED AREA 6 INCH BY 1 INCH S-27 L, BS 1004 TO BS 1010 ON STRINGER. SPLICED IN NEW STRINGER SECTION WEIGHT CHANGE LESS THAN 1 LB. REPAIRED PER SRM 53-10-3. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)