What was found
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND CORROSION 2 INCHES BY 2 INCHES, STA 312 RBL 35 INCHES ON FLOOR BEAM. REPLACED T-CAP FROM LBL 6 TO RBL 36, REPAIRED PER TR 53-10-13. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-3' CHECK VISUAL INSPECTION, FOUND CORROSION 2 INCHES BY 2 INCHES, STA 312 RBL 35 INCHES ON FLOOR BEAM. REPLACED T-CAP FROM LBL 6 TO RBL 36, REPAIRED PER TR 53-10-13. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (X)