What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK LBL 25 LONGITUDINAL FLOOR BEAM WEB (LOWER) STATION 707, WL 203. INSTALLED WEB REPAIR (WT .3 LBS), REPAIRED PER SRM 51-40-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK LBL 25 LONGITUDINAL FLOOR BEAM WEB (LOWER) STATION 707, WL 203. INSTALLED WEB REPAIR (WT .3 LBS), REPAIRED PER SRM 51-40-2. (M)