As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 1 INCH TO 2 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES BS 987 LBL 45 TO RBL 45 ON FLOOR BEAM. SPLICED IN T-CAP. REPAIRED PER EA 40379, CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)