As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PIT - DURING Q-5 CHECK INSPECTION, FOUND LEVEL 1 CORROSION PREVIOUSLY REWORKED FROM LONGERON 28R-29R AT STATION 1338 T-CAP ANGLES AND WEB. CORROSION TASK REF C50-53300. REMOVED CORROSION AND INSTALLED DOUBLER REPAIR PER USAIR TYPICAL REPAIR 53-30-10. (M)