What was found
CLT - CLT INSPECTION FOUND BY EDDY CURRENT A 1.7 INCH FLOOR BEAM CRACK LOCATED AT STATION 520 EXTENDING 6 INCHES INBOARD OF RBL 24.75. INSTALLED REPAIR DOUBLERS AS PER USAIR EA NR 40294. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - CLT INSPECTION FOUND BY EDDY CURRENT A 1.7 INCH FLOOR BEAM CRACK LOCATED AT STATION 520 EXTENDING 6 INCHES INBOARD OF RBL 24.75. INSTALLED REPAIR DOUBLERS AS PER USAIR EA NR 40294. (M)