PIT - Q1/C2 INSPECTION, FOUND CORROSION ON STRINGER NR 3 AT STATION 12791 TO STATION 13851. SPLICED IN NEW SECTION OF STRINGER NR 3 PER SRM 51-70-06 REPAIR NR 5. (M)