What was found
PIT - Q1/C2 INSPECTION, FOUND CORROSION ON STRINGER NR 3 STATION 11257. SPLICED IN NEW SECTION OF STRINGER PER SRM 51-70-06 REPAIR NR 5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - Q1/C2 INSPECTION, FOUND CORROSION ON STRINGER NR 3 STATION 11257. SPLICED IN NEW SECTION OF STRINGER PER SRM 51-70-06 REPAIR NR 5. (M)