What was found
INT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 30 PERCENT CORRODED Z-ANGLE FORWARD GALLEY ENTRANCE, STATION 277 AND STATION 344. REMOVED AND REPLACED NR ME-32 REQUIRED. REPAIRED PER SRM 51-10-2. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (M)