What was found
INT - DURING 'Q-2' CHECK VISUAL INSPECTION, FOUND .50 INCH BY .50 INCH HOLE AT WEB OF FLOOR BEAM, STA 1016 PLUS 6 INCHES, RBL 6. INSTALLED DOUBLER. REPAIRED PER SRM 51-40-2. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING 'Q-2' CHECK VISUAL INSPECTION, FOUND .50 INCH BY .50 INCH HOLE AT WEB OF FLOOR BEAM, STA 1016 PLUS 6 INCHES, RBL 6. INSTALLED DOUBLER. REPAIRED PER SRM 51-40-2. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (X)