What was found
INT - DURING 'Q-2' CHECK VISUAL INSPECTION, FOUND SEVERAL CRACKS IN HOLES BETWEEN S20L AND S21L, ONE, .50 INCH CRACK AT ATTACH HOLE FOR TRANSITION ANGLE FRAME, BS 460, LEFT SIDE. CUT OUT CRACK AT TRANSITION AREA OF FRAME AND BETWEEN S20L AND S21L. MANUFACTURED, HEAT TREATED, AND INSTALLED REPAIR AND FILLER. REPAIRED PER SRM 20-30-06, SRM 53-10-4. (X)