INT - DURING 'Q-2' CHECK VISUAL INSPECTION FOUND 1.25 INCH CRACK LBL 25 LONGITUDINAL FLOOR BEAM AT AILERON QUADRANT STA 676. WL 206.5. INSTALLED DOUBLER, REPAIRED PER EA 40395, EO 5791G632. (X)