What was found
PIT - DURING Q-1 INSPECTION, FOUND CORROSION ON FLOOR BEAM BLO AT STATION 3845 T-CAP. REMOVED SECTION OF CORRODED T-CAP FROM STATION 3845 TO 5315 AND SPLICED IN NEW SECTION PER SRM 53-21-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 INSPECTION, FOUND CORROSION ON FLOOR BEAM BLO AT STATION 3845 T-CAP. REMOVED SECTION OF CORRODED T-CAP FROM STATION 3845 TO 5315 AND SPLICED IN NEW SECTION PER SRM 53-21-10. (M)