What was found
PIT - DURING Q-1 INSPECTION, FOUND CORROSION .005 INCH TO .053 INCH ON FLOOR BEAM AT STATION 1127R FWD OF FRAME 4850. REPLACED SECTION OF BEAM FROM STATION 4850 TO 5305 PER SRM 53-21-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 INSPECTION, FOUND CORROSION .005 INCH TO .053 INCH ON FLOOR BEAM AT STATION 1127R FWD OF FRAME 4850. REPLACED SECTION OF BEAM FROM STATION 4850 TO 5305 PER SRM 53-21-10. (M)