What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND CORROSION AT STRINGER 27R STATION 1006, 2 INCH BY 1 INCH. REPAIRED AND REPLACED SHORT STRINGER SECTION WITH NEW COMPLETE STRINGER. REPAIRED PER SRM 51-10-1. CORROSION TASK NR C53-208-01, CORROSION LEVEL 2. (M)