What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .1250 INCH CRACK IN STRINGER 5L TIE CLIP AT BS 727A. REPLACED CLIP, REPAIRED PER EO NR 5394G227. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .1250 INCH CRACK IN STRINGER 5L TIE CLIP AT BS 727A. REPLACED CLIP, REPAIRED PER EO NR 5394G227. (M)