What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK IN STRINGER CLIP, AT BS 639 STRINGER 6R. REPLACED CLIP, REPAIRED PER EO 5393G227. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK IN STRINGER CLIP, AT BS 639 STRINGER 6R. REPLACED CLIP, REPAIRED PER EO 5393G227. (M)