What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK STATION 616, STRINGER 2L TIE CLIP. INSTALLED NEW TIE CLIP. REPAIRED PER EO 5393G227. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK STATION 616, STRINGER 2L TIE CLIP. INSTALLED NEW TIE CLIP. REPAIRED PER EO 5393G227. (M)