What was found
CLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION, 3 INCHES BY 3 INCHES ON WEB, LOCATED AT BS 1016 THROUGH BL0. INSTALLED DOUBLERS, FILLERS AND STIFFENERS AS PER USAIR SRM 53-80-08, 51-70-11 AND 53-80-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION, 3 INCHES BY 3 INCHES ON WEB, LOCATED AT BS 1016 THROUGH BL0. INSTALLED DOUBLERS, FILLERS AND STIFFENERS AS PER USAIR SRM 53-80-08, 51-70-11 AND 53-80-01. (M)