As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 50 INCHES CORRODED FLOOR BEAM BS 294.5 RBL 6, RBL 56. INSTALLED T-CAP AND REPAIR ANGLES AND FILLER, REPAIRED PER SRM 53-10-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)