What was found
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH CORROSION IN SEVERAL AREAS (NUTPLATES HOLES) BS 285 TO BS 355 RIGHT SIDE Z-ANGLE. REMOVED DAMAGED ANGLE COMPLETED INSTALLATION OF Z-ANGLE AND REPAIR PARTS. REPAIRED PER SRM 51-10-2. CORROSION TASK NR C52-107-02, CORROSION LEVEL 2. (M)