INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK UPPER T-CAP IN RADIUS BS 520 RBL 45.5, BEAM. CONTAINED CRACK INSTALLED U-CHANNEL AND RADIUS BLOCKS AND COMPLETED REPAIR, EA 40649. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK UPPER T-CAP IN RADIUS BS 520 RBL 45.5, BEAM. CONTAINED CRACK INSTALLED U-CHANNEL AND RADIUS BLOCKS AND COMPLETED REPAIR, EA 40649. (M)