INT - DURING DROP IN CHECK VISUAL INSPECTION, FOUND .125 INCH CRACK IN 2 STRINGER TIE CLIPS BS 616 AT STRINGER 2L AND STRINGER 4L. REPAIRED PER EO 5393G227. MODIFIED PART NR 69-35352-14. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING DROP IN CHECK VISUAL INSPECTION, FOUND .125 INCH CRACK IN 2 STRINGER TIE CLIPS BS 616 AT STRINGER 2L AND STRINGER 4L. REPAIRED PER EO 5393G227. MODIFIED PART NR 69-35352-14. (M)