PIT - DURING Q-4 INSPECTION, FOUND LEVEL 1 CORROSION ON LONGERON 30 FROM STATION 1285 TO STATION 1295. CORROSION TASK NR C57-53300. CUT OUT CORRODED SECTION OF LONGERON AND ACCOMPLISHED SPLICE REPAIR PER DACO DWG 5936667. (M)