What was found
PIT - DURING Q-4 INSPECTION, FOUND LEVEL 1 CORROSION AT LONGERON 29L STATION 1231-1250 AROUND AND AT RIVETS. CORROSION TASK NR C57-53300. SPLICED IN NEW SECTION OF LONGERON PER USAIR EA 31905. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-4 INSPECTION, FOUND LEVEL 1 CORROSION AT LONGERON 29L STATION 1231-1250 AROUND AND AT RIVETS. CORROSION TASK NR C57-53300. SPLICED IN NEW SECTION OF LONGERON PER USAIR EA 31905. (M)