What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 45 INCH CORROSION FLOOR BEAM STATION 967 BL 0 TO LBL 45. INSTALLED ONE DUOBLER AT LBL 42, REPAIRED PER TR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 45 INCH CORROSION FLOOR BEAM STATION 967 BL 0 TO LBL 45. INSTALLED ONE DUOBLER AT LBL 42, REPAIRED PER TR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)