What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 20 INCH BY 1 INCH FLOOR SUPPORT ANGLE CORROSION STATION 967 TO 947 RBL 6. REPAIRED PER SRM 51-10-1. REPLACED WITH IDENTICAL PART NR 65C10592-2. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)