What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 20 INCH CORRODED FLOOR SUPPORT ANGLE STATION 986.5 TO 967 LBL 12. REPLACED ANGLE, REPAIRED PER SRM 51-10-1. CORROSION TASK NR 53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 20 INCH CORRODED FLOOR SUPPORT ANGLE STATION 986.5 TO 967 LBL 12. REPLACED ANGLE, REPAIRED PER SRM 51-10-1. CORROSION TASK NR 53-107-02, CORROSION LEVEL 2. (M)