What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 3 CORRODED AREAS APPROXIMATELY 1 INCH BY 1 INCH ON INTERCOSTAL, RBL 10 INCHES BETWEEN BS 294.5 AND BS 312. REPLACED INTERCOSTAL, REPAIRED PER SRM 51-10-1 AND BOEING DRAWING 65-45834. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)