What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 2 INCH CORROSION 8 INCH FLOOR SUPPORT INTERCOSTAL STATION 986.5 LNL 15 INCHES. REPLACED WITH IDENTICAL PART NR 65-46812-191, REPAIRED PER SRM 51-10-1. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)