What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 4 INCH BY 4 INCH CORRODED WEB AFT ENTRY DOOR Z-ANGLE THRESHOLD WEB. FABRICATED NEW WEB, REPAIRED PER SRM 51-10-1 AND BOEING DRAWING 65-52878. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (M)