What was found
PIT - DURING Q-1 CHECK INSPECTION, FOUND 3 INCH CRACK FRAME STATION 1491 BL 883L HIGH FREQUENCY EDDY CURRENT INSPECTION. STOP DRILLED CRACK AND INSTALLED DOUBLERS PER USAIR EA NR 32077. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK INSPECTION, FOUND 3 INCH CRACK FRAME STATION 1491 BL 883L HIGH FREQUENCY EDDY CURRENT INSPECTION. STOP DRILLED CRACK AND INSTALLED DOUBLERS PER USAIR EA NR 32077. (M)