What was found
PIT - DURING Q-1 CHECK INSPECTION, FOUND 1 INCH CRACK, FRAME STATION 14911 BL 883 R (HFEC INSPECTION). STOP DRILLED CRACK AND INSTALLED DOUBLERS PER USAIR EA NR 32077. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-1 CHECK INSPECTION, FOUND 1 INCH CRACK, FRAME STATION 14911 BL 883 R (HFEC INSPECTION). STOP DRILLED CRACK AND INSTALLED DOUBLERS PER USAIR EA NR 32077. (M)