What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .5 BY 32 INCH CORROSION FLOOR BEAM BS 294 RBL 7 - RBL 60. INSTALLED T-CAP AND REPAIRED ANGLES PER SRM 53-10-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .5 BY 32 INCH CORROSION FLOOR BEAM BS 294 RBL 7 - RBL 60. INSTALLED T-CAP AND REPAIRED ANGLES PER SRM 53-10-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)