What was found
INT - DURNG Q-6 CHECK VISUAL INSPECTION, FOUND 4 INCH AND .75 INCH GOUGE IN SKIN AT BS 800 BETWEEN STRINGER 22R AND STRINGER 24R. INSTALLED DOUBLER PER SRM 53-00-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURNG Q-6 CHECK VISUAL INSPECTION, FOUND 4 INCH AND .75 INCH GOUGE IN SKIN AT BS 800 BETWEEN STRINGER 22R AND STRINGER 24R. INSTALLED DOUBLER PER SRM 53-00-01. (M)