What was found
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORRODED NUT PLATE HOLES AT FLOOR BEAM STATION 460-500 ABOVE STRINGER 27 R. REPLACED ANGLE, REPAIRED PER SRM 53-10-5 FIG 6. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORRODED NUT PLATE HOLES AT FLOOR BEAM STATION 460-500 ABOVE STRINGER 27 R. REPLACED ANGLE, REPAIRED PER SRM 53-10-5 FIG 6. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)