What was found
PIT - DURING Q-3/C-5 CHECK INSPECTION, FOUND LEVEL I CORROSION FORWARD CARGO LOWER DOOR PAN AT STATION 370 TO 427. CORROSION TASK NR C51-53300. REMOVED AND REPLACED LOWER PAN WITH MODIFIED PAN P/N J060228-3 PER SRM 53-05 FIG 44. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PIT - DURING Q-3/C-5 CHECK INSPECTION, FOUND LEVEL I CORROSION FORWARD CARGO LOWER DOOR PAN AT STATION 370 TO 427. CORROSION TASK NR C51-53300. REMOVED AND REPLACED LOWER PAN WITH MODIFIED PAN P/N J060228-3 PER SRM 53-05 FIG 44. (M)