What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 30 INCH BY 1 INCH FLOOR BEAM STATION 1006 BL '0' TO LBL 30. INSTALLED FILLER AND STRAPS, REPAIRED PER TR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 30 INCH BY 1 INCH FLOOR BEAM STATION 1006 BL '0' TO LBL 30. INSTALLED FILLER AND STRAPS, REPAIRED PER TR 53-10-01A. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)