What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 5 INCH BY 2 INCH, 1 INCH BY 2 INCH AND 1 INCH BY 4 INCH FLOOR BEAM STATION 967 LBL 6, LBL 30, LBL 20 TO LBL 25. INSTALLED T-CAP, REPAIRED ANGLES AND STRAPS. REPAIRED PER TR 53-10-05C. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)