As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND SIX 1 INCH BY 1 INCH CORRODED AREA AT FLOOR BEAM BS 344 LBL 50 INCH TO BL 'O'. SPLICED IN NEW SECTION OF T-ANGLE CAP. INSTALLED REPAIR ANGLES. REPAIRED PER TR 53-10-13. CORROSION TASK NR C53-107-01, CORROSION LEVEL 2. (M)